Essential Tips for PCR & DNA Cleanup: Maximize Your DNA Purity and Yield

Posted on Monday, March 10, 2025

By Joanne Gibson, Ph.D., Illustrations by Tasha José

Topic: Tips for the lab

Purifying DNA after PCR amplification or enzymatic reactions is a critical step in molecular biology workflows. Removing enzymes, primers, nucleotides, and buffer components ensures that your DNA is ready for downstream applications like cloning, sequencing or labeling. While PCR cleanup protocols are generally straightforward, following best practices can significantly enhance the yield and purity of your DNA. Here are some expert tips and tricks for each step of the DNA cleanup process: Bind, Wash and Elute.

(1) Bind Your DNA Efficiently

Infographic showing steps of binding DNA to a matrix in a microfuge tube.

Efficient binding of DNA to the purification matrix is crucial for high recovery rates. This step ensures that your DNA is securely attached to the column matrix, allowing impurities to be washed away in subsequent steps.

 

Orange circle with white check mark in it

DO:

  • Monitor sample volume and DNA quantity:
    - Sample volume: A starting volume of 20–100 μl is recommended. If your sample volume is less than 20 μl, adjust it by adding nuclease-free water or TE buffer.
    - DNA quantity: Do not exceed the column's binding capacity (e.g., 5 μg for the Monarch® Spin Columns S1A, provided with the Monarch Spin PCR & DNA Cleanup Kit, NEB #T1130). Overloading can lead to poor binding and lower yields.
  • Use the correct binding buffer: Make sure you're using the binding buffer provided with your kit, such as the Monarch Buffer BZ (supplied with the Monarch Spin PCR & DNA Cleanup Kit), which is optimized for efficient DNA binding without the need to monitor pH.
  • Ensure proper mixing: Thoroughly mix your sample with the binding buffer to facilitate optimal interaction between the DNA and the matrix.
  • Adjust for small DNA fragments: If purifying small DNA fragments (50 bp) or oligonucleotides, modify the protocol by adding additional alcohol to the sample before binding, which will increase the binding efficiency for small DNA. With the Monarch Spin PCR & DNA Cleanup Kit, a separate protocol is provided for small DNA or oligonucleotide cleanup. Please refer to the provided protocol for detailed guidance.

Orange circle with white X

DON'T:

  • Overload the column: Exceeding the maximum DNA capacity can result in inefficient binding and reduced yield. If you have more DNA, split the sample across multiple columns.
  • Skip incubation times: Allow sufficient time for the DNA to bind to the matrix as per the protocol. Rushing this step can decrease binding efficiency.
  • Use incompatible buffers: Avoid using binding buffers not specified for your kit, as they may not support optimal DNA binding.

 


 

(2) Wash Your DNA Thoroughly

Infographic showing steps of washing DNA bound to a matrix in a microfuge tube.

Proper washing is essential to remove impurities such as salts, enzymes, and unincorporated nucleotides that can interfere with downstream applications.

 

Orange circle with white check mark in it

DO:

  • Use the provided wash buffers:
    - First wash: Use the initial wash buffer, such as Monarch Buffer WZ, to remove most contaminants.
    - Second wash: Perform a second wash to ensure all residual impurities are eliminated.
  • Ensure complete removal of wash buffer:
    - Spin for the full time: After the final wash, centrifuge the column for the recommended time (typically 1 minute) to remove all traces of ethanol.
    - Avoid column tip contamination: Make sure the tip of the column does not touch the flow-through in the collection tube during transfers. Any residual ethanol from the wash buffer can affect downstream applications. If in doubt, perform an additional spin.

Orange circle with white X

DON'T:

  • Skip wash steps: Omitting any wash steps can leave residual contaminants that may inhibit downstream enzymatic reactions.
  • Rush the process: Insufficient washing or centrifugation can result in carryover of impurities.
  • Let column touch flow-through: Contaminating the column tip with wash buffer flow-through can reintroduce impurities.

 


 

(3) Elute Your DNA Carefully

Infographic showing steps of eluting DNA from a matrix in a microfuge tube.

Elution is the final step where purified DNA is released from the column matrix. Proper elution ensures you recover DNA in a suitable concentration and volume for your downstream applications.

 

Orange circle with white check mark in it

DO:

  • Use the recommended elution buffer:
    - Monarch Buffer EY: This buffer (10 mM Tris, 0.1 mM EDTA, pH 8.5) is ideal for eluting DNA and is suitable for long-term stability.
  • Optimize elution volume: The optimal elution volume range is 5–20 μl. To obtain highly concentrated DNA, elute in less volume, as little as 5 μl with Monarch Spin kits.
  • Pre-warm elution buffer (if necessary): For larger DNA Fragments (>10 kb), pre-warm the elution buffer to 50°C and extend the incubation time on the column to at least 5 minutes to enhance recovery.
  • Apply elution buffer correctly:
    - Center the buffer: Apply the elution buffer directly to the center of the column matrix to ensure even distribution.
    - Incubate properly: Allow the buffer to sit on the column for at least 1 minute before centrifugation to maximize elution efficiency.

Orange circle with white X

DON'T:

  • Use incompatible elution buffers: If using water instead of the provided buffer, ensure it is nuclease-free and pH-adjusted to 7–8.5. Milli-Q™ water can be slightly acidic and may require pH adjustment.
  • Shorten incubation times: Skipping or shortening the recommended incubation can lead to incomplete elution and lower DNA yield.
  • Store DNA in unstable conditions:
    - Avoid magnesium-containing solutions: Do not store DNA in solutions with magnesium, as it can promote degradation.
    - Improper storage temperature: For long-term storage, keep your DNA at –20°C to maintain its integrity. 

 


 

Additional Tips for Optimal DNA Purification

Monitor DNA Quality:
Check Purity Ratios: Use a spectrophotometer to measure A260/280 and A260/230 ratios. A pure DNA sample typically has an A260/280 ratio around 1.8 and an A260/230 ratio between 2.0–2.3. Assess DNA Integrity: Run an aliquot on an agarose gel to verify the size and integrity of your DNA.

Handle DNA Gently:
Avoid Vortexing: During binding and elution steps, mix by gentle inversion to prevent shearing of DNA, especially if working with large fragments. Prevent DNA Denaturation: Overexposure to chaotropic salts can denature DNA. Follow incubation times carefully.

By following these tips and best practices, you can achieve high-quality DNA purification, ensuring the success of your downstream applications. Remember that each step—Bind, Wash and Elute—is crucial for maximizing yield and purity.

Consider Using the Monarch® Spin PCR & DNA Cleanup Kit (5 μg) (NEB #T1130)

The Monarch Spin PCR & DNA Cleanup Kit (5 μg) provides a fast and reliable method for purifying up to 5 μg of concentrated, high-quality DNA from PCR and other enzymatic reactions.

Advantages of the Monarch Spin PCR & DNA Cleanup Kit:

  • High Recovery Rates: Efficiently purifies DNA fragments from 50 bp up to 25 kb.
  • Low Elution Volumes: Elute in as little as 5 μl for highly concentrated DNA.
  • No Need to Monitor pH: The optimized buffer system allows for effective DNA binding without pH adjustments.
  • Fast Protocols: Reduce hands-on time with quicker procedures and less centrifugation.
  • Flexible: Protocol modification for oligonucleotide cleanup is provided, allowing purification of ssDNA, oligonucleotides and other small DNA fragments, without the need to purchase another kit.
  • Easy to Swap Applications: Monarch Spin DNA Gel Extraction Kits and Monarch Spin PCR & DNA Cleanup Kits share components, except for the binding buffer. Purchase the additional buffer and follow the appropriate protocol to unlock another application.
  • Convenience: Additional columns and buffers can be purchased separately to fit your workflow needs.
  • Environmentally Friendly Design: The kit uses significantly less plastic in columns, buffers, and packaging compared to leading suppliers.

 

FAQs and Technical Support
For more information and troubleshooting tips, you can access a full list of FAQs for the Monarch Spin PCR & DNA Cleanup Kit. You can also contact Technical Support for additional advice.

 

Learn More About Monarch Nucleic Acid Purification Kits

 

 

 

NEB will not rent, sell, or otherwise transfer your data to a third party for monetary consideration. See our Privacy Policy for details. View our Community Guidelines.

Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. All other trademarks are the property of their respective owners. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.

 