Perform USER Excision and PCR Library Enrichment (E7445)
Protocol
The Universal PCR primer and Index (X) Primer, and USER Enzyme are contained in the NEBNext Singleplex (NEB #E7350) or NEBNext Multiplex (NEB #E7335 or NEB #E7500) Oligos for Illumina. If you are using alternate oligos which are not supplied by New England Biolabs, it will be necessary to purchase USER Enzyme separately (NEB #M5505).- To the size selected cDNA (20 μl) add the following components:
USER Enzyme 3 μl
NEBNext High-Fidelity PCR Master Mix, 2X 25 μl
Universal PCR Primer (25 μM) 1 μl
Index (X) Primer (25 μM)* 1 μl
------------------------------------------------------------------------
Total volume 50 μl
* If you are using the NEBNext Multiplex Oligos for Illumina (E7335 or E7500 ) for each reaction, only one of the 12 PCR primer indices is used during the PCR step.
- PCR Cycling Conditions
CYCLE STEP TEMP TIME CYCLES User Digestion 37°C 15 minutes 1 Initial Denaturation 98°C 10 seconds 1 Denaturation 98°C 10 seconds 12-15* Annealing 65°C 30 seconds Extension 72°C 30 seconds Final Extension 72°C 5 minutes 1 Hold 4°C ∞
- Purify the PCR reaction using AMPure XP Beads (strongly recommended).
CYCLE STEP | TEMP | TIME | CYCLES |
User Digestion | 37°C | 15 minutes | 1 |
Initial Denaturation | 98°C | 10 seconds | 1 |
Denaturation | 98°C | 10 seconds | 12-15* |
Annealing | 65°C | 30 seconds | |
Extension | 72°C | 30 seconds | |
Final Extension | 72°C | 5 minutes | 1 |
Hold | 4°C | ∞ | |