NEB will be closed Thursday, November 23, 2017 and Friday, November 24, 2017. Orders placed will process Monday, November 27, 2017 for delivery on Tuesday, November 28,2017.

FAQ: How does the level of star activity of NcoI-HF compare to NcoI?

The Fidelity Index which measures the minimum units to produce star activity was determined using the following conditions; 1X NEBuffer, 5% glycerol, lambda DNA (1µg/50 µl), incubated for 1 hour at 37˚C . The minimum number of units of NcoI-HF required to produce star activity in the recommended NEBuffer 4 is (≥16,000 units). The minimum number of units of NcoI required to produce star activity in the recommended NEBuffer 3 is (120 units).The minimum number of units of NcoI required to produce star activity in NEBuffer 4 is (32 units).

Links to this resource

Related Products:
NcoI-HF®
Loading Spinner