Effective August 26, 2024, product name modified to Monarch® Spin gDNA Extraction Kit. The component/product name of Monarch gDNA Purification Columns has changed to Monarch Spin Columns S2C, and these columns are now tinted orange.
Extract and purify genomic DNA from a broad range of sample types, such as cells, blood, tissue, bacteria, yeast, saliva, swabs with just this single kit. Suitable for clinically-relevant samples (e.g., saliva, cheek).
Isolate high molecular weight gDNA (peak size typically ≥ 50 kb) for use directly in downstream applications, including PCR, qPCR/RT-qPCR, NGS and sequencing.
Obtain excellent yields of highly-pure DNA with very low residual RNA contamination (typically <1%) with included RNase A and Proteinase K.
Protocol compatible for cleanup of gDNA from other purifications.
Kit components and columns also offered separately.
For HMW gDNA extraction up to Mb range for long-read sequencing, see related Monarch HMW DNA Extraction Kit for Cells & Blood (NEB #T3050) or Monarch HMW DNA Extraction Kit for Tissue (NEB #T3060).
Check out our Technical Note containing comprehensive insights into measuring and analyzing nucleic acids.
The Monarch Spin gDNA Extraction Kit is a comprehensive solution for cell lysis, RNA removal, and purification of intact genomic
DNA (gDNA) from a wide variety of biological samples, including cultured cells, blood, and mammalian tissues. Additionally, bacteria
and yeast can be processed with extra steps to enhance lysis in these tough-to-lyse samples. Protocols are also included to enable
purification from clinically-relevant samples such as saliva and cheek swabs as well as rapid cleanup of previously extracted gDNA.
Purified gDNA has high quality metrics, including A260/A280 > 1.8 and A260/A230 > 2.0, high DIN scores and minimal residual RNA. The
purified gDNA is suitable for downstream applications such as end-point PCR, qPCR and library prep for NGS. It typically has
a peak size of > 50kb, making this kit an excellent choice upstream of long-read sequencing platforms.
Specifications:
Input:
Cultured mammalian cells: up to 5 x 106 cells
Mammalian whole blood: 100 µl
Tissue: up to 25 mg, depending on tissue type
Bacteria: up to 2 x 109
Yeast: up to 5 x 107
Saliva: up to 500 µl
Buccal swabs
Genomic DNA requiring cleanup
Binding Capacity:
30 µg genomic DNA
Yield:
Varies depending on sample type
Genomic DNA Size:
Peak size > 50 kb for most sample types; may be lower for saliva and buccal swabs
RNA Content
< 1% (with included RNase A treatment)
Elution Volume
≥35 µl, but 100 µl is recommended
Purity:
A260/280 ≥ 1.8
A260/230 ≥ 2.0
Validated Sample Types:
Mouse Tail
Mouse Ear
Mouse Liver
Rat Liver
Mouse Kidney
Mouse Spleen
Mouse Heart
Mouse Lung
Mouse Brain
Rat Brain
Mouse Muscle
Rat Muscle
Deer Muscle
Human Blood
Mouse Blood
Rabbit Blood
Pig Blood
Guinea Pig Blood
Cow Blood
Horse Blood
Dog Blood
Chicken Blood
HeLa Cells
HEK293 Cells
NIH3T3 Cells
E. coli
Rhodobacter sp.
B. cereus
T. kodakarensis
S. cerevisiae
Saliva
Buccal swab
This product is related to the following categories:
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.
Specifications & Change Notifications
Effective August 26, 2024, product name modified to Monarch®Spin gDNA Extraction Kit. The component/product name of Monarch gDNA Purification Columns has changed to Monarch Spin Columns S2C, and these columns are now tinted orange.
Effective March 14, 2024: Proteinase K, Molecular Biology Grade component number has changed with the concentration changing from 800U/ml to 20 mg/ml.
Effective May 9, 2022: Shelf life is 24 months.
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.
This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
Based on your Freezer Program type, you are trying to add a product to your cart that is either not allowed or not allowed with the existing contents of your cart. Please review and update your order accordingly. If you have any questions, please contact Customer Support at freezers@neb.com or 1-800-632-5227 x 8.
You have been idle for more than 20 minutes, for your security you have been logged out. Please sign back in to continue your session.
Institution Changed
Your profile has been mapped to an Institution, please sign back for your profile updates to be completed.
Sign in to your NEB account
To save your cart and view previous orders, sign in to your NEB account. Adding products to your cart without being signed in will result in a loss of your cart when you do sign in or leave the site.